Technical Specifications
-
Processor & Memory:
- 256 MHz 32-bit Freescale ColdFire processor with dual-core architecture for parallel task execution.
- 64 MB RAM for real-time data processing and 4 MB ROM for firmware storage.
- 2 MB NVRAM (non-volatile memory) with battery backup for configuration retention .
-
Input/Output (I/O) Capacity:
- Supports 30,000+ function blocks and handles 5,000+ I/O points in closed-loop control with <250 ms cycle time .
- Compatible with S800 I/O, Harmony Rack I/O, and S+HART I/O subsystems for flexible signal integration .
-
Communication:
- Dual Ethernet ports (10/100 Mbps) supporting Modbus TCP, PROFIBUS DP, and HART protocols.
- Redundant CW800 peer-to-peer communication bus for controller synchronization with <100 ms update rate .
- Optional IEC 61850 and DNP 3.0 support for smart grid and substation automation .
-
Power Supply:
- 24 V DC ±20% input with reverse polarity protection.
- 5 W typical power consumption (8 W max under full load) .
-
Physical Dimensions:
- 243.84 mm (height) × 78.74 mm (depth) × 210.82 mm (width).
- Weight: 0.88 kg (aluminum housing with EMI shielding) .
-
Environmental Ratings:
- Operating temperature: -20°C to +60°C (extended industrial range).
- IP20 protection against solid particles.
- Compliance with EN 61000-6-2/4 for EMC immunity and emissions .
-
Redundancy:
- 1:1 hot-standby redundancy with <50 ms switchover time for critical applications.
- Redundant power supplies and internal buses eliminate single points of failure .
Functional Features
-
Real-Time Control:
- Executes 8 partitioned tasks with 1 ms minimum cycle time, supporting IEC 61131-3 programming languages (Ladder Logic, Structured Text) .
- Built-in PID control, batch processing, and advanced regulatory control (ARC) algorithms.
-
Modular Scalability:
- Expandable via HN800 redundant I/O bus to connect 64+ I/O modules (local or remote).
- Field-upgradable firmware for protocol updates and feature enhancements .
-
Diagnostics & Safety:
- LED indicators for power, communication, and fault status.
- SIL 2-compliant (IEC 61508) when paired with safety-certified I/O modules.
- Hot-swap capability for module replacement without system downtime .
-
Device Integration:
- Direct integration with HART-enabled sensors and PROFIBUS DP slaves via PDP800 interface modules.
- Supports S+Engineering Composer software for centralized configuration and diagnostics .
-
Cybersecurity:
- ISA Secure certification for industrial-grade protection against cyber threats.
- TLS encryption for Modbus TCP and HART communication .
Application Scenarios
-
Power Generation:
- Hydro/Wind Turbines: Controls turbine speed, blade pitch, and grid synchronization.
- Thermal Power Plants: Manages boiler feedwater systems and steam turbine efficiency .
-
Water/Wastewater Treatment:
- Supervises pH/conductivity monitoring, pump stations, and disinfection processes.
- Integrates with SCADA systems for remote asset management .
-
Process Industries:
- Oil & Gas: Optimizes pipeline pressure/temperature control and emergency shutdown systems.
- Pharmaceuticals: Ensures ±0.1% accuracy in batch reactor processes with recipe management .
-
Smart Grids:
- Monitors grid voltage/frequency and coordinates distributed energy resources (DERs) via IEC 61850.
- Enables demand response programs and microgrid load balancing .
Key Benefits
-
Reliability:
- MTBF >200,000 hours under rated conditions.
- Dual-core architecture with hardware-based error correction .
-
Energy Efficiency:
- Reduces power consumption by 25% through optimized signal conditioning.
- Supports IEC 61850-90-7 for interoperable energy management .
-
Cost Savings:
- Self-diagnostic features minimize maintenance costs.
- Hot-swap capability reduces downtime during module replacement .
-
Future-Proofing:
- Backward compatibility with Symphony Plus legacy systems.
- Scalable to 32 modules per rack via HN800 backplane .
Compliance & Certifications
- Safety: SIL 2 (IEC 61508), UL 61010-1, CSA C22.2.
- EMC: EN 61000-6-2 (industrial immunity), EN 61000-6-4 (emissions).
- Environmental: RoHS 2011/65/EU and REACH SVHC compliant.
- Cybersecurity: ISA Secure certification for industrial-grade protection .
Typical Use Case
Substation Automation:
- HC800 interfaces with 10+ IEDs (Intelligent Electronic Devices) using IEC 61850 for real-time data acquisition.
- Configurable channels accommodate Modbus RTU for legacy devices and DNP 3 for grid-level control.
- Result: Reduced communication latency (<100 ms) and 99.9% uptime during grid fault scenarios .
Installation Notes
- Torque Specs: Terminals must be tightened to 4–6 N·m to prevent arcing.
- Network Configuration: Redundant Ethernet ports should use IEEE 802.3ad link aggregation for high availability.
- Cybersecurity: Enable TLS 1.2 encryption for Modbus communication and restrict unused ports .
- Cabling: Use shielded twisted-pair cables for RS-485 connections to minimize interference.
Discover our other products
KEBA KEBA TI-570 / TI570 (NEW IN BOX)
KEBA KEBA E-8-THERMO/A / E8THERMOA (NEW NO BOX)
KEBA Teaching Pendant KEBA KETOP O70-BRA-A0A-F With Cable
KEBA 1PC New ABB/KEBA SX TPU 2 16/64 3HAC023195-001 ROBOT IRC5
KEBA ONE New ABB/KEBA SX TPU 2 16/64 3HAC023195-001 ROBOT IRC5
KEBA 100% test KEBA CU312 90days warranty Free DHL or EMS
KEBA 1PC New ABB/KEBA SX TPU 2 16/64 3HAC023195-001 ROBOT IRC5
KEBA 1PCS ABB/KEBA SX TPU 2 16/64 3HAC023195-001 ROBOT IRC5 NEW
KEBA 1PCS New ABB/KEBA SX TPU 2 16/64 3HAC023195-001 ROBOT IRC5
KEBA ONE ABB/KEBA SX TPU 2 16/64 3HAC023195-001 ROBOT IRC5 NEW





There are no reviews yet.